Cais
▲ system cyflenwi dŵr cartref mewn adeiladau uchel, ardaloedd domestig trefol a gwledig, mentrau ac ati.
▲ defnydd dŵr diwydiannol fel dŵr oeri, cylch dŵr rhwydwaith gwresogi, dŵr porthiant boeler.
▲ systemau rheoli pwysedd cyson hylif masnachol eraill.

Nodweddion Cynhyrchion
● Lleihau'r straen cychwynnol ar gyfer y system bwmpio.
● Cyflymder optimaidd ar gyfer y galw ar unwaith.
● Optimeiddio'r defnydd o ynni mewn systemau pwmp cyfochrog (atgyfnerthu).
● Atal cafn pwmp a rhedeg sych.
● Monitro'r defnydd o ynni.
● Monitro a diogelu'r modur pwmp.
Paramedrau Cynnyrch

Data Technegol
| Model | Pŵer | Foltedd mewnbynnu | Llif wedi'i Ail-wneud (m3/h) | Pennaeth wedi'i Raddio (m) | Model PUMP tri cham | Amlder allbwn | Synhwyrydd pwysedd |
| VFWI-15S/1-18 | 0.25KW | 1x220V | 1.0 | 18 | CMI1-2T (△) | 20--50Hz | 4--20mA, +24V, (10bar, 16bar, 25bar) |
| VFWI-15S/1-25 | 0.25KW | 1x220V | 1.0 | 25 | CMI1-3T (△) | ||
| VFWI-15S/1-33 | 0.37KW | 1x220V | 1.0 | 33 | CMI1-4T (△) | ||
| VFWI-15S/1-38 | 0.37KW | 1x220V | 1.0 | 38 | CMI1-5T (△) | ||
| VFWI-15S/1-46 | 0.37KW | 1x220V | 1.0 | 46 | CMI1-6T (△) | ||
| VFWI-15S/2-18 | 0.25KW | 1x220V | 2.0 | 18 | CMI2-2T (△) | ||
| VFWI-15S/2-24 | 0.37KW | 1x220V | 2.0 | 24 | CMI2-3T (△) | ||
| VFWI-15S/2-32 | 0.55KW | 1x220V | 2.0 | 32 | CMI2-4T (△) | ||
| VFWI-15S/2-40 | 0.55KW | 1x220V | 2.0 | 40 | CMI2-5T (△) | ||
| VFWI-15S/2-47 | 0.75KW | 1x220V | 2.0 | 47 | CMI2-6T (△) | ||
| VFWI-15S/3-15 | 0.25KW | 1x220V | 3.0 | 15 | CMI3-2T (△) | ||
| VFWI-15S/3-21 | 0.37KW | 1x220V | 3.0 | 21 | CMI3-3T (△) | ||
| VFWI-15S/3-28 | 0.55KW | 1x220V | 3.0 | 28 | CMI3-4T (△) | ||
| VFWI-15S/3-34 | 0.55KW | 1x220V | 3.0 | 34 | CMI3-5T (△) | ||
| VFWI-15S/3-38 | 0.75KW | 1x220V | 3.0 | 38 | CMI3-6T (△) | ||
| VFWI-15S/4-15 | 0.37KW | 1x220V | 4.0 | 15 | CMI4-2T (△) | ||
| VFWI-15S/4-25 | 0.55KW | 1x220V | 4.0 | 25 | CMI4-3T (△) | ||
| VFWI-15S/4-30 | 0.75KW | 1x220V | 4.0 | 30 | CMI4-4T (△) | ||
| VFWI-15S/4-40 | 1.0KW | 1x220V | 4.0 | 40 | CMI4-5T (△) | ||
| VFWI-15S/4-49 | 1.3KW | 1x220V | 4.0 | 49 | CMI4-6T (△) | ||
| VFWI-15S/5-13 | 0.37KW | 1x220V | 5.0 | 13 | CMI5-2T (△) | ||
| VFWI-15S/5-23 | 0.55KW | 1x220V | 5.0 | 23 | CMI5-3T (△) | ||
| VFWI-15S/5-27 | 0.75KW | 1x220V | 5.0 | 27 | CMI5-4T (△) | ||
| VFWI-15S/5-35 | 1.0KW | 1x220V | 5.0 | 35 | CMI5-5T (△) | ||
| VFWI-15S/5-44 | 1.3KW | 1x220V | 5.0 | 44 | CMI5-6T (△) | ||
| VFWI-15S/8-12 | 0.55KW | 1x220V | 8.0 | 12 | CMI8-10T (△) | ||
| VFWI-15S/8-20 | 0.75KW | 1x220V | 8.0 | 20 | CMI8-15T (△) | ||
| VFWI-15S/8-24 | 1KW | 1x220V | 8.0 | 24 | CMI8-20T (△) | ||
| VFWI-15S/8-27 | 1.5KW | 1x220V | 8.0 | 27 | CMI8-25T (△) | ||
| VFWI-15S/8-36 | 1.85KW | 1x220V | 8.0 | 36 | CMI8-30T (△) | ||
| VFWI-15S/8-43 | 2.2KW | 1x220V | 8.0 | 43 | CMI8-35T (△) | ||
| VFWI-15S/8-48 | 2.2KW | 1x220V | 8.0 | 48 | CMI8-40T (△) | ||
| VFWI-15S/8-9 | 0.55KW | 1x220V | 8.0 | 9 | CMI8-10BT (△) | ||
| VFWI-15S/8-19 | 0.75KW | 1x220V | 8.0 | 19 | CMI8-20BT (△) | ||
| VFWI-15S/8-26 | 1.1KW | 1x220V | 8.0 | 26 | CMI8-30BT (△) | ||
| VFWI-15S/8-37 | 1.5KW | 1x220V | 8.0 | 37 | CMI8-40BT (△) | ||
| VFWI-15S/8-46 | 2.2KW | 1x220V | 8.0 | 46 | CMI8-50BT (△) | ||
| VFWI-15S/10-11 | 0.65KW | 1x220V | 10.0 | 11 | CMI10-1T (△) | ||
| VFWI-15S/10-24 | 1.2KW | 1x220V | 10.0 | 24 | CMI10-2T (△) | ||
| VFWI-15S/10-37 | 2.2KW | 1x220V | 10.0 | 37 | CMI10-3T (△) | ||
| VFWI-15S/12-13 | 1KW | 1x220V | 12.0 | 13 | CMI12-10T (△) | ||
| VFWI-15S/12-20 | 1.5KW | 1x220V | 12.0 | 20 | CMI12-15T (△) | ||
| VFWI-15S/12-28 | 1.65KW | 1x220V | 12.0 | 28 | CMI12-20T (△) | ||
| VFWI-15S/12-33 | 2.2KW | 1x220V | 12.0 | 33 | CMI12-25T (△) | ||
| VFWI-15S/12-9 | 0.75KW | 1x220V | 12.0 | 9 | CMI12-10BT (△) | ||
| VFWI-15S/12-19 | 1.1KW | 1x220V | 12.0 | 19 | CMI12-20BT (△) | ||
| VFWI-15S/12-29 | 1.85KW | 1x220V | 12.0 | 29 | CMI12-30BT (△) | ||
| VFWI-15S/12-39 | 2.2KW | 1x220V | 12.0 | 39 | CMI12-40BT (△) | ||
| VFWI-15S/15-12 | 1.2KW | 1x220V | 15.0 | 12 | CMI15-1T (△) | ||
| VFWI-15S/15-29 | 2.2KW | 1x220V | 15.0 | 29 | CMI15-2T (△) | ||
| VFWI-15S/16-10 | 1KW | 1x220V | 16.0 | 10 | CMI16-10T (△) | ||
| VFWI-15S/16-20 | 1.5KW | 1x220V | 16.0 | 20 | CMI16-20T (△) | ||
| VFWI-15S/16-30 | 2.2KW | 1x220V | 16.0 | 30 | CMI16-30T (△) | ||
| VFWI-15S/20-10 | 1KW | 1x220V | 20.0 | 10 | CMI20-10T (△) | ||
| VFWI-15S/20-20 | 1.85KW | 1x220V | 20.0 | 20 | CMI20-20T (△) |
CAOYA
▲A yw'r mewnbwn un cam a'r math o allbwn tri cham yn gwrthdröydd tri cham?
Ar gyfer pympiau dŵr, mae'n dri cham. Ar gyfer pympiau dŵr, ein cyfres "S" yw tri cham 220V ac mae "T" yn dri cham 380V.
▲Beth mae'n ei olygu bod y gwrthdrowr yn addasu i'r pŵer modur o dan 2.2KW?
Mae'n golygu y gellir ei ddefnyddio ar gyfer 0.75KW, 1.1KW, 1.5KW, 2.2KW (pŵer o dan 2.2KW) pwmp dŵr.
▲Faint o wrthdroyddion y gellir eu cysylltu ar-lein ar y mwyaf?
Gall ein gwrthdroyddion gysylltu 6 dyfais ar yr un pryd.
▲A fyddwn yn gwneud y dirywiad pan fyddwn yn gosod y gwrthdrowr ar y pwmp dŵr? Er enghraifft, 3kg, 5 kg, 10 kg.
Na, does dim angen i chi wneud hynny. Bydd y gwrthdrowr yn addasu'r pwysau'n awtomatig yn ôl pwysau'r pwmp.
▲A oes gan y pwmp dŵr amledd amrywiol amser gweithio parhaus? Er enghraifft, 73 awr o waith parhaus?
Ar gyfer un pwmp dŵr VFD yn unig, NA; ar gyfer math o gysylltiad aml-bwmp sy'n fwy na dau bwmp, mae ganddynt.
▲Ar ôl y diogelwch dros dymheredd, pryd fydd pwmp dŵr VFD yn gweithio fel arfer?
Bydd yn gweithio fel arfer pan fydd y tymheredd yn gostwng yn is na 60°C.
▲A oes diagram sgematig o'r cysylltiad pwmp gwrthdro a diagram cysylltu'r cysylltiad gwrthdro?
Gwiriwch y llun amgaeedig:


Tagiau poblogaidd: Pwmp dŵr trosi amlder VSD, Tsieina, cyflenwyr, ffatri, wedi'i haddasu, rhad, rhestr brisiau, dyfyniad